Conv. Samtec40 to Samtec22 PowerTrace Serial for TriCore AGBT


The embedded tools company




Support
Technical Support
 

Target Adaptation Conv. Samtec40 to Samtec22 for PowerTrace Serial for TriCore AGBT


Product

Order No.Probe
LA-3556AGBT Trace Adapter for PowerTrace Serial 



Target Connector Type

SAMTEC Part NumberDescription
ASP-137969-01Rugged High Speed Socket

Data Sheet
Link to SAMTEC

Target Connector Placement

The adaption uses a 22-pin Samtec connector. Recommendation is to place the even numbered pins at the PCB border side so the flex cable won't be twisted.

Pinout

Trace Signals

VREF is mandatory for a correct operation of the preprocessor. Keep unused lanes unconnected.

Debug Signals

The pinout of the 22-pin Samtec connector optionally includes the debug signals. The trace converter has a 16-pin JTAG connector and an AUTO26 connector where the user can plug the Debug Cable. This saves the need for a separate debug connector on the target.

The debug signals are TCK, TMS, TRST-, TDI, TDO, RESET- and TRIG (user defined). By default, the TRIG pin is connected to the OCDSE-/WDTDIS signal of the debug cable. This allows controlling an external watchdog, see chapter "Controlling an External Watchdog" in Application Note Debug Cable TriCore. For special cases only there is a soldering option to route the TRIG pin to the BRKIN-, BRKOUT- or USER0 signal of the debug cable. Contact technical support for more information.

Alternatively the Debug Cable can be plugged on a separate debug connector (JTAG, DAP or AUTO) on the target. In this case there is no need to connect the debug signals to the 22-pin Samtec connector. This avoids stubs and may improve signal quality.

Signal

Pin

 Pin

Signal

    
RXP012VREF
RXN034TCK
GND56TMS
RXP178TDI
RXN1910TDO
GND1112TRST-
RXP21314CLKP
RXN21516CLKN
GND1718TRIG
RXP31920CRCERR
RXN32122RESET-
    
Target connector, top-view, connect the two latch pins to GND